Product Details:
|
The Range Of Temperature: | Room Temperature To 500 ℃ | The Temperature Resolution: | 0.1 ℃ |
---|---|---|---|
Heating Rate: | 0.1 ~ 80 ℃ / Min | DSC Range: | 0 ~ + 200 Mw |
DSC Resolution: | 0.01 MW | DSC Sensitivity: | 0.1 MW |
Power Supply: | AC 220 V, 50 Hz Or Custom | Plastic Testing Equipment: | Differential Thermal Analyzer |
High Light: | impact test equipment,material testing machine |
Differential Thermal Analyzer Plastic Testing Equipment For Oxidation Induction Period Test
Technical parameters:
1: the range of temperature: room temperature to 500 °C
2: the temperature resolution: 0.1 °C3: heating rate: 0.1 ~ 80 °C / min
4: DSC range: 0 ~ + 200 mw
5: DSC resolution: 0.01 mW
6: DSC sensitivity: 0.1 mW
7: working power supply: AC 220 v, 50 hz or custom
Technical Feature:
1) Widescreen touch structure of industrial level, rich display information, including the set
temperature, sample temperature, oxygen flow rate,Nitrogen flow, differential thermal signals, all kinds of switch state, flow goes to zero.
2) USB communication interface, generality is strong, reliable communication don't interrupt,
support the restore connection function.
3) Furnace structure is compact, arbitrary adjustable cooling rate.
4) Improved installation process, all adopt the machinery fixed way, completely to avoid contamination
of furnace inside colloid to differential thermal signal.
5) Double temperature probe, make sure the height of the sample temperature measurement
repeatability. Temperature sensor is installed on furnace walls all the way, used for PID control of the
furnace body temperature, but due to the temperature of thermal inertia, conduction to the temperature
on the sample have some deviation, and deviation degree of winters is different, therefore, with one
temperature probe temperature control and temperature measurement, differential thermal signals and
temperature signals, the error is larger; The instrument in the bottom of the sample how to install a
temperature probe, used to measure the real temperature of the sample, and used our special
temperature control technology, control the temperature of furnace wall temperature to reach the set
temperature.
6) Digital gas mass flowmeter atmosphere automatic switching two way traffic, fast switching and stable
time is short.
7) Standard standard samples, convenient customer constant temperature correction coefficient.
8) Software adaptive resolution of computer screens, each software automatically according to the
computer screen size to adjust the curve display mode. Support for notebook, desktop; Support the
Win2000, XP, VISTA, Windows 7 operating system, etc
8) Support user programming procedures, to achieve fully automated measuring step. Software provides
dozens of commands, users can according to your own measurement steps, and combined the orders,
and save. Complex operation is simplified into a key operation.
DSC-500A Touch screen type
It can only test the oxidation induction priod(OIT)