Product Details:
|
Power: | AC220V±10% 50Hz | Plastic Testing Machine: | Melt Flow Index Tester |
---|---|---|---|
Temperature Rangeradius: | 400℃ | Temperature Accuracyblade To Jawand Dust Collector: | ±0.2 ℃ |
Display Resolution: | 0.1℃ | Maximum Comsuption: | < 600W |
Temperature Recovery Time: | Less Than 4 Min. | Name: | MFR Melt Flow Index Machine , Electronic Plastic Testing Instrument |
High Light: | impact test equipment,material testing equipment |
MFR Melt Flow Index Machine , Electronic Plastic Testing Instrument
Brief introduction
1.Purpose:
Melt flow rate tester (also known as melt index meter) was measured under certain conditions thermoplastic melt flow rate of the special equipment. With the determination of melt flow rate MFR, measured melt volume rate MVR, measured melt density ρ, measured melt flow rate ratio FRR and other functions, this machine high precision temperature control, key parts nitriding treatment, high strength and hardness , small deformation accurately measure the flow rate which provides a good condition.
MFR Melt Flow Index Machine , Electronic Plastic Testing Instrument
2.Principle:
Thermoplastic melt flow rate (melt index) is plastic at a temperature and load, the melt every 10 minutes through a standard capillary die quality or melt volume, with MFR (MI) or the MVR value, which can distinguish thermoplastic adhesive in the molten state flow characteristics. For thermoplastics and chemical fiber raw materials, quality assurance of products and other products of great significance.
Technical parameter:
Machine size(W*H*D) |
250*510*350mm |
Power |
AC220V±10% 50Hz |
Barrel parameters |
Inner hole 9.55±0.025mm |
Pistons parameters |
Piston head: 9.475±0.015mm |
Piston length |
H=6.35±0.1mm |
Paramters |
Extrusion hole 1=2.095±0.005mm |
Temperature parameter |
With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade |
Temperature rangeradius |
400℃ |
Temperature accuracyblade to jawand dust collector |
±0.2 ℃ |
Display resolution |
0.1℃ |
Maximum comsuption |
< 600W |
Temperature recovery time |
less than 4 min. |
Weight parameters |
|
Weight accuracy |
±0.5% |
Basic configuration |
0.325kg, 1.2kg, 2.16kg, 3.8kg, 5.kg, 10.0kg, 12.kg, 21.6kg |
Position detection |
|
Loop distance from up and down |
30mm |
Control precision |
± 0.1mm |
Test flow control |
|
Times of cutting the material |
0~10 times |
Material cutting interval |
0~999s(set reference Table 2) |
Control flow reaches the set temperature without volatility |
|
Barrel temperature time |
15 min. |
Material be installed |
1 min |
Material sample temperature recovery time |
4 min. |
When binder set |
1min |