Product Details:
|
Material: | Steel | Size: | Customized |
---|---|---|---|
Temperature: | -70℃~150℃ | Humidity: | Double 85 Testing |
Color: | Customized | Controller: | TM880 |
Highlight: | constant temperature and humidity chamber,stability test chamber |
OEM Lab Test Machine Temperature Humidity Test Chamber Customized
Usage :
Humidity and Temperature Control Testing Chamber used to test various types of materials for their tolerances of heat, cold, dry, humidity. It is applied for for all types of electronic products,electric appliance, and products from communication, instrument, automobile, plastic, metal, food, chemical,building materials, medical and aerospace industries.
Feature
materials | shell | the double-sided with cold-rolled steel while the surface with spray | |
inner | the SUS304 stainless steel | ||
insulation | rigid polyurethane foam and glass fiber | ||
regulating system | heater | nickel-chromium alloy heating wire | |
humidifier | stainless steel armored heater (basin heated humidification) or boiler humidification | ||
fan | centrifugal fan | ||
cold compressor | hermetic , low noisy and rotary compressor | ||
cooling fluid | R404A | R404A/R23 | |
cooling method | single stage mechanized compression (air cooling or water cooling) | double stage mechanized compression (air cooling or water cooling) | |
controller | display | 5.7 inches color LCD display | |
operation mode | program mode and valuation method | ||
setting type | available in Chinese and English, LCD touch screen | ||
capacity | it can store 120 sets program, 1,200-section, 999-circular steps,and setting maximal time for every section is 999h59min. | ||
display resolution | 0.01centigrade,0.1min,0.01%RH(if it has the humidity function) | ||
input | Pt100Ω | ||
communication interface | R232 | ||
control type | PID | ||
water supply | supply method | pumped | |
water tank | built-in | ||
quality | resistor>500Ωm | ||
Security protection |
electric leakage protection, protection of blower overheating, over-current, over-temperature and water system(only humidity and hot )and water-breaking (cooling only), compressor 's over-pressure, dry protector and temperature fuse |
Technical parameter:
Mode |
LY-280 |
LY-2150 |
LY-2225 |
LY-2408 |
LY-21000 |
|
Inner Size W×H×D(cm) |
40×50×40 |
50×60×50 |
60×85×80 |
60×85×80 |
100×100×100 |
|
Outside Size W×H×D(cm) |
93×155×95 |
100×148×106 |
117×166×91 |
140×176×101 |
170×186×111 |
|
Volume (V) |
80 L |
150L |
225L |
408L |
800L |
|
Temp and Hum Range |
A:-20°C~150°C B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C RH20%-98% |
|||||
Function |
Fluctuation |
±0.5°C ±2.5%RH |
||||
Deviation |
±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH) |
|||||
Controller Analytical Accuracy |
±0.3°C ±2.5%RH |
|||||
Material |
Inner Wall |
#SUS 304 Stainless steel |
||||
Outer Skin |
#SUS 304 Stainless steel |
|||||
Heat Preservation |
High temperature resistant, high chlorine acid b vinegar foam insulation materials |
|||||
Wind Cycling Way |
Centrifugal fan-broadband type forced air circulation |
|||||
Refrigeration Way |
Single stage compression refrigeration |
|||||
Refrigerater |
French Tecumseh |
|||||
Refrigerants |
R4O4A USA Dupont environmental protection refrigerant(R23+R404) |
|||||
Condensing Way |
Air-cooled or water-cooled |
|||||
Heater |
Nickel chrome heating wire heater |
|||||
Humidifier |
Semi-closed steam and wet |
|||||
Water Suplying Way |
Automatic cycling water supply |
|||||
Standard Accessories |
1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 clapboards, 1 bag of wet and dry bulb, 3 fuses, 1 power line. |
|||||
Safety device |
Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system |
Picture showing :
Contact Person: Victoria Li
Tel: +8613809275028
Fax: 86-769-28682030