Product Details:
|
Inner Size W×H×D(cm): | 40×50×40 | External Size W×H×D(cm): | 93×155×95 |
---|---|---|---|
Volume(L): | 80 L | Humi Control Range: | RH20%-98% |
Temp Control Range: | -40°C~150°C | Compressor: | Imported From France |
High Light: | abrasion testing machine,adhesion testing equipment |
CE Certificate Temperature And Humidity Chamber For Testing Tape Adhesiveness
Usage
Widely use for stickers, protective film, all types of films for aging resistance by stimulate certain temperature and humidity. It is used for observing whether there is adhesiveness issue after putting the product
Characteristic
1. LCD touch screen.
2. Easy operation & maintenance.
3. Inner material: SUS#304.
4. CE certified and quality guaranteed
Specifications:
Model |
LY-280 |
LY-2150 |
LY-2225 |
LY-2408 |
LY-2800 |
LY-21000 |
|
Inner Size W×H×D(cm) |
40×50×40 |
50×60×50 |
50×75×60 |
60×85×80 |
100×100×80 |
100×100× 100 |
|
External Size W×H×D(cm) |
93×155×95 |
100×148× 106 |
117×166× 118 |
122×176× 121 |
158×186× 148 |
158×195× 168 |
|
Volume(L) |
80 L |
150L |
225L |
408L |
800L |
1000L |
|
Temp&Humi Control Range |
Temp. Range: A: -20°C~150°C Humi.range: RH20%-98% B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C (Other temperature and humidity range can be customized) |
||||||
Temp&Humi Fluctuation |
±0.5°C;±2.5%RH |
||||||
Temp&Hum Departure |
±0.5°C-±2°C;±3%RH(>75%RH); ±5%RH(≤75%RH) |
||||||
Controller Resolution |
±0.3°C;±2.5%RH |
||||||
Controller Brand |
Korean TEMI880 |
||||||
Material |
Inwall |
SUS 304# steel plate |
|||||
|
Housing |
SUS 304# steel plate surface fog processed |
|||||
|
Heat Insulator |
resistance to high temperature, high chlorine acid b vinegar foam insulation materials |
|||||
Aie Circulation Way |
centrifugal fan-broadband type force air circulation |
||||||
Refrigeration Way |
cascade type multiple refrigeration |
||||||
Refrigerater |
fully enclosed piston compressor Taikang France |
||||||
Refrigerants |
R4O4Aor American dupont environmental protection cold media(R23+R404) |
||||||
Condensing Way |
Air-cooling |
||||||
Heater |
nickel chrome heating wire heater |
||||||
Humidifier |
semi-closed steam |
||||||
Water Supply Way |
automatic cycle water supply |
||||||
|
|||||||
Safety Devices |
*Leakage current *Overload *Compressor overload *Over temperature *Ultra-wet/dry *Humidification temperature protection. |
||||||
Power |
380V or 220V AC±10% 50/60Hz |