Product Details:
|
Material: | Steel | Size: | Customized Based On Rquirements |
---|---|---|---|
Temperature: | -70℃~150℃ | Humidity: | 20%-98% |
Color: | Customized | Controller: | TM880 |
High Light: | constant temperature and humidity chamber,stability test chamber |
OEM Temperature And Humidity Controlled Chamber Lab Test Machine
Usage :
This equipment is widely applied for electronic and electric products ,components and material by
constant high low temperature, temperature change ,cycling ,damp heat etc environment simulation
reliability testing.
Standard Features:
Testing Standard Compliance:
GB2423.1-2008(IEC68-2-1)Environmental testing - Part 2: Test methods - Tests A: Cold
GB2423.2-2008(IEC68-2-2)Environmental testing for electric and electronic products Test methods - Tests B:Dry Heat GB2423.3-2006(IEC68-2-3)Environmental testing for electric and electronic products - Part 2: Testing method test Cab: Damp heat Steady state
GB2423.4-2008(IEC68-2-30)Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat,cyclic ( 12h+12h cycle)
GB2423.22-2008(IEC68-2-14)Environmental testing for electric and electronic products-Part 2:Test methods-Test N:Change of temperature GJB150.3A-2009(MIL-STD-810D)High temperature test
GJB150.4A-2009(MIL-STD-810D)Low temperature test
GJB150.9A-2009(MIL-STD-810D)Damp heat test .
Technical parameter:
Mode |
LY-280 |
|||||
Inner Size W×H×D(cm) |
40×50×40 |
|||||
Outside Size W×H×D(cm) |
45×155×95 |
|||||
Volume (V) |
80 L |
|||||
Temp and Hum Range |
A:-20°C~150°C B: -40°C~150°C C: -60°C~150°C D: -70°C~150°C RH20%-98% |
|||||
Function |
Fluctuation |
±0.5°C ±2.5%RH |
||||
Deviation |
±0.5°C-±2°C ±3%RH(>75%RH); ±5%RH(≤75%RH) |
|||||
Controller Analytical Accuracy |
±0.3°C ±2.5%RH |
|||||
Material |
Inner Wall |
#SUS 304 Stainless steel |
||||
Outer Skin |
#SUS 304 Stainless steel |
|||||
Heat Preservation |
High temperature resistant, high chlorine acid b vinegar foam insulation materials |
|||||
Wind Cycling Way |
Centrifugal fan-broadband type forced air circulation |
|||||
Refrigeration Way |
Single stage compression refrigeration |
|||||
Refrigerater |
French Tecumseh |
|||||
Refrigerants |
R4O4A USA Dupont environmental protection refrigerant(R23+R404) |
|||||
Condensing Way |
Air-cooled or water-cooled |
|||||
Heater |
Nickel chrome heating wire heater |
|||||
Humidifier |
Semi-closed steam and wet |
|||||
Water Suplying Way |
Automatic cycling water supply |
|||||
Standard Accessories |
1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 clapboards, 1 bag of wet and dry bulb, 3 fuses, 1 power line. |
|||||
Safety device |
Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system |