Product Details:
|
Test Chamber Capacity(L): | 270L | Test Chamber Size: | 90*60*50 Cm |
---|---|---|---|
Max Volum Of Test Liquid(L): | 108L | Volume: | 141*88*128cm |
Voltage: | 220V | Controller: | PID Controller |
Warranty Period: | 12 Months | Usage: | Salt Spray Corrosion Test Chamber |
Power: | Electronic | Material: | PVC Material |
Highlight: | salspray test equipment,salt spray corrosion test chamber |
270L Environment Salt Spray Corrosion Test Chamber PVC Coating
Introduction:
Salt spray test chamber can determine the corrosion resistance of iron metal or the iron metal inorganic film or organic film test, such as: electroplating, anode processing, conversion coating, painting, ect.
Design standards:
ISO9227,CNS3627,3885,4159,7669,8886,JIS D-0201,H-8502,H-8610,K-5400,Z-2371,ISO 3768,3769,3770,ASTM B-117,B-268,GB-T2423,GJB 150.
Characteristics:
1.LCD display and a pid controller or touch screen programmable controller.
3.Entire PVC sheet material, the internal ring with the use of advanced three-dimensional flutter high technology products, strong structure, fresh, never deformation and acid and alkali
, high temperature and never aging, for salt spray, copper acetate, and other test specifications.
4.Controller are in the same panel, the operation simple and clear.
5.Neutral salt spray (NSS), acetic acid salt spray ( AASS ), copper accelerated salt spray ( CASS ) either
of the test laboratory
Specifications:
Model: | LY-609-90 |
Inner Box Size (L×W×H) |
90×60×50 cm |
Outside Box Size(L×W×H) : | 114×88×128 cm |
Temperature Range : | 35°C~55 °C |
Temperature Fluctuations : | ≤±0.5°C |
Temperature Uniformity : | ±1°C |
Brine Temperature : | 35°C±1°C |
Spray Quantity : | 1.0~2.0 ml / 80cm2 / hr |
Lab Volume : | 270L |
Brine Tank Capacity : | 25L |
Power : | AC220V,10A |
Accessories : | Testing Salt/ Measuring tank/ Equipment each 1 set |
Equipment Material | Both inside & outside shell adopt imported P.V.C rigid plastic board, and tank cover uses imported transparent P.V.C. rigid plastic board |
Test Chamber Temperature | Salt Spray Method (NSS ACSS)35±1°C Corrosion-resistant Testing Method(CASS)50±1°C |
Saturated air Barrel Temperature | Salt Spray Method (NSS ACSS)47±1°C Corrosion-resistant Testing Method(CASS)63±1°C |
PH | Salt Spray Method (NSS ACSS6.5~7.2)Corrosion-resistant Testing Method(CASS)3.0~3.2 |
Multiple Safety Protection Devices : | Current discharge protection, over pressure protection,over temperature protection, over load fuse protection |
Customize parts:
1. Inner chamber size
2. Inner chamber structure
3. PID programmable controller or PLC touch screen controller
Contact Person: Ms. Victoria Li
Tel: +8613809275028
Fax: 86-769-28682030